Finding your Alfa Laval AC heat exchanger. The Alfa Laval AC line of brazed plate heat exchangers are available in four models, corresponding to different maximum design pressures and optimized for use with different refrigerants:AC units 32 bar. ACH units 45 bar. ACK units 49 bar.
AC230 brazed plate heat exchanger with a single refrigerant circuit unit. It is suitable to work as an evaporator and as condenser. CB60, copper brazed plate heat exchanger. The brazing material seals and holds the plates points ensuring optimal heat transfer efficiency and pressure resistance. AXP52 is a brazed plate heat exchanger with thin Brazed plate heat exchanger - All industrial manufacturers The GBE/GKE-Series are compact brazed plate heat exchangers designed for hydronics, perfectly suitable for applications with up to 30 bar / 435 psi and max. 200°C / 392°F. They Compare this product Remove from comparison tool. See the other products. Ecoflex.
30 years of constant development. The performance and efficiency of the brazed plate heat exchanger (BPHE) have been proven through 30 years of constant development to ensure high thermal efficiency leading to energy savings in air conditioning systems. With its ingenious construction of corrugated plates, the BPHE EnFusion brazed plate heat exchanger PHEB3-014 EnFusion brazed plate heat exchanger PHE is the ideal choice for air driers and chill- ers, heat pump, economizers, desuperheaters and can be used for numerous other appli- cations. The heat exchanger is designed to combine high thermal efficiency with energy savings. Capacity:0.5 - 5 kW.
Brazed plate heat exchangers do not contain rubber gaskets and can therefore operate continuously at extreme temperatures from -180°C to 200°C with operating pressures as high as 30 bar. Applications where these heat exchangers are an effective solution include heating and ventilation (for solar heating and air-conditioning units), heat pumps, heat recovery, and hydraulic oil units. SL34 - DanfossCopper and Stainless Steel Brazed Plate Heat Exchangers Technical Information Standard Materials: Flow plates and connections:AISI 316 End plates:AISI 304 Brazing material:Copper or stainless steel Design Pressure: Copper brazed:25 or 30 Bar (362 or 435 PSI) Sonder Safe:30 Bar (435 PSI) Design Temperature: Copper and stainless steel brazed:÷100 to 185°C (÷148 to 365°F)
EWT-N4-30 Nickel brazed plate heat exchanger Suitable for demineralized water, ammonia - NH3, galvanized piping, laser-cooling :Plate Material:1.4401; AISI 316 (V4A) Braze Material:Nickel:Length x Width:306 mm x 106 mm:Connectors:4 x G 1" Male:Operating pressure:Maximum 10 bar Vol.15 - Brazed Plate Heat Exchanger (BPHE) as an BPHEs can typically tolerate a temperature range of -160 Deg C to +150 Deg C. Pressures are usually limited to 30 bar (440 psig). The burst pressure of a BPHE should be as high as 150 bar (2200 psig) since many pressure vessel safety codes call for five times the maximum working pressure (now to be termed Maximum Allowable Pressure under BS.4434) where the pressure resistance cannot be
The heat exchanger is designed to combine high thermal efficiency with energy savings. B3-052. Capacity :10 60 kW. Refrigerants :R407C, R22, R404A, R410A, R134A. Design temperature :196 to +200ºC/320 to +392ºF. Standard design pressure :30